Product description
Innovaflex® ADC grades are biopharmaceutical pump tubings specially formulated for ADC application, and can be also used in other single use assemblies, pumping, process filling and sampling applications in bioprocessing. They have very low particle spallation during pumping process, clear clarity, smoother inner and outter surface, and the most importantly, are specially formulated to resist against 100% DMSO and DMF either pre or post-gamma irradiation. Innovaflex® ADC pharmaceutical grades are ideal replacement to imported brands such as AdvantaFlex®, CFlex®, BioFlex® and is an ideal tubine option for ADC application. Innovaflex® ADC is FDA DMF III registered.
Features Physical properties Regulations Resistance to DMSO and DMF
Hardness Shore A : 65A USP Class VI Non-animal derived and nonhemolytic
Specific gravity : 0.89g/cm3 ISO 10993 Sterilizable by ETO, autoclave, Gamma Tensile strength : 11.2MPa FDA 21CFR 177.2600 Manufactured in ISO 7 clean room Elongation : 650% USP 665, 788, 661
Full validation and extractables studies Max working temperature : 135C FDA DMF III registered Coil length are available from 25 to 100 ft upon request.
Other ID x OD size are available and special sizes can be customized.
All custom products are subject to minimum order quantities and lead times.
For other custom options, please contact us at info@innovapure.com .AdvantaFlex® is trademark of Newage Industry; CFlex® is trademark of Saint Gobain; BioFlex® is trademark of Meissner.
Product description
Innovaflex® ADC grades are biopharmaceutical pump tubings specially formulated for ADC application, and can be also used in other single use assemblies, pumping, process filling and sampling applications in bioprocessing. They have very low particle spallation during pumping process, clear clarity, smoother inner and outter surface, and the most importantly, are specially formulated to resist against 100% DMSO and DMF either pre or post-gamma irradiation. Innovaflex® ADC pharmaceutical grades are ideal replacement to imported brands such as AdvantaFlex®, CFlex®, BioFlex® and is an ideal tubine option for ADC application. Innovaflex® ADC is FDA DMF III registered.
Features | Physical properties | Regulations |
Resistance to DMSO and DMF |
Hardness Shore A : 65A | USP Class VI |
Non-animal derived and nonhemolytic |
Specific gravity : 0.89g/cm3 | ISO 10993 |
Sterilizable by ETO, autoclave, Gamma | Tensile strength : 11.2MPa | FDA 21CFR 177.2600 |
Manufactured in ISO 7 clean room | Elongation : 650% | USP 665, 788, 661 |
Full validation and extractables studies | Max working temperature : 135C | FDA DMF III registered |
Coil length are available from 25 to 100 ft upon request.
Other ID x OD size are available and special sizes can be customized.
All custom products are subject to minimum order quantities and lead times.
For other custom options, please contact us at info@innovapure.com .
AdvantaFlex® is trademark of Newage Industry; CFlex® is trademark of Saint Gobain; BioFlex® is trademark of Meissner.